Releases: powsybl/powsybl-open-loadflow
Releases · powsybl/powsybl-open-loadflow
v1.13.2
v1.13.1
v1.13.0
Release notes
Update to PowSyBl Core 6.5.0 (#1094, #1100)
Features
- Remove grouping by element necessary to connectivity (#1060)
- Support of Hvdc line loss in AC emulation (#1062)
- DC sensitivity analysis: remove factors in connectivity break analysis (#1073)
- Add category keys to Parameters (#1071)
- Multi-thread security analysis (#1079)
- Fast restart for active power target change (#1085)
- Avoid slack distribution to fictitious loads (#1028)
- Fast DC security analysis using Woodbury engine (#1072)
- Security analysis: run simulation on all components (#1089)
- Add transformer voltage control already exists report in LfNetworkLoaderImpl (#1088)
- Area Interchange Control as OuterLoop (#1055)
- Retrieve specific parameters overrides from PlatformConfig (#1093)
Fixes
- Fix log for switching PQ to PV (#1067)
- At most one flow/factor states calculation for one contingency in DC sensitivity analysis (#1061)
- Security Analysis: fix Generator initialTargetP in OperatorStrategies (#1069)
- AC loadflow: no network update on NO_CALCULATION (#1075)
- Fix LimitViolation data for three-windings transformers (#1076)
- Fix StaticVarCompensator and VscConverter used as reference generator (#1078)
- Fix slack distribution when reference generator is not participating element (#1084)
- Fix unpaired DanglingLine simulated with split shunt admittance (#1098)
- Fix SA exception "No slack bus for network" (#1097)
Quality
- Extract Woodbury engine from DC sensitivity analysis (#1064)
- Remove log.txt (#1066)
- Move runDcLoadFlow from DC sensitivity analysis to DcLoadFlowEngine (#1082)
- Move cleanContingencies from DC sensitivity analysis to PropagatedContingency utility method (#1081)
Documentation
v1.12.2
v1.11.1
v1.12.1
V1.12.0
Important
The DC Sensitivity Analysis refactoring introduces a huge memory consumption which leads to OutOfMemoryErrors.
Use powsybl-open-loadflow 1.12.1 instead.
Release notes
Upgrade to PowSyBl Core 6.4.0 (#1034, #1054)
Features
- Improve transformer voltage control
AFTER_GENERATOR_VOLTAGE_CONTROL(#1032) - Implement minTargetP and maxTargetP from ActivePowerControl extension (#1043)
- Fictitious generators and condensers controlling voltage even if stopped (#1044)
Fixes
- Fix limits handling in slack distribution on generators (#1041)
Dependencies
Quality
- Refactor DC Sensitivity Analysis with Woodbury engine (#1001)
V1.11.0
Release notes
Fixes
- Fix and improve reactiveRangeCheckMode parameter documentation (#1049)
- Fix allowed direction in incremental outer loops (#1052)
- Fix state monitor duplicated results with tie lines (#1051)
- Use existing threshold for filtering sensitivity of injection over voltage and voltage over injection (#1047)
- Fix cache invalidation when change on another component (#1039)
- DC security analysis: RHS is not invalidated (#1042)
- Fix bus imbalance with slack distribution on load (#1040)
- Fix transformer voltage control outer loop AFTER GENERATOR (#1038)
- Fix Q dispatch not accounting for plausible reactive power range (#1037)
Quality
- Readthedocs: simple transfer from website (#1046)
v1.10.0
Release notes
- Add Battery case for getIdentifiable for Propagated Contingency (#1018)
- Absolute generator action ignores post-contingency slack (#1017)
- Support generator remote reactive control on 3 windings transformer terminal (#1026)
- Improve logging, reporting and LF results for components without generators (#919)
- Report network angle reference bus and slack bus(es) after network loading (#1029)
- Use IIDM OverLoadManagementSystem (#946)
- Improve LoadFlowResult ComponentResult statusText (#1023)
- Add reports in LfNetworkLoaderImpl (#1020)
- Check target voltage plausibility on Transformers and Shunt Compensators (#1030)
- Add operator strategy simulation report node (#1031)
- Slack bus relocation (#923)
- Minimal support of limit reductions for security analysis (#1011)
Fixes
- Fix debugDir parameter possible values (#1021)
- Fix Battery update state after voltage control (#1027)
- Fixed Static VAR Compensator OFF mode having NaN P and Q results (#1033)
- Connectivity data in DC sensitivity analysis (#1035)
- Secondary voltage control: re-enable generators at limit when updating a control zone (#1022)
Quality
- Add missing spdx license identifier (#1019)