Release notes

Dependencies

  • Bump powsybl-core to 6.5.1 (#1110)

Fixes

  • Fix Security Analysis in case of no more voltage regulated bus (#1096)
  • Fix high memory usage with DC Sensitivity Analysis and DC Woodbury Security Analysis (#1109)

v1.13.1

18 Oct 08:06
v1.13.1
72fe988

Choose a tag to compare

Release notes

  • Fix secondary voltage control in case of generators with remote volage control (#1103)

v1.13.0

11 Oct 14:38
v1.13.0
00026e6

Choose a tag to compare

Release notes

Update to PowSyBl Core 6.5.0 (#1094, #1100)

Features

  • Remove grouping by element necessary to connectivity (#1060)
  • Support of Hvdc line loss in AC emulation (#1062)
  • DC sensitivity analysis: remove factors in connectivity break analysis (#1073)
  • Add category keys to Parameters (#1071)
  • Multi-thread security analysis (#1079)
  • Fast restart for active power target change (#1085)
  • Avoid slack distribution to fictitious loads (#1028)
  • Fast DC security analysis using Woodbury engine (#1072)
  • Security analysis: run simulation on all components (#1089)
  • Add transformer voltage control already exists report in LfNetworkLoaderImpl (#1088)
  • Area Interchange Control as OuterLoop (#1055)
  • Retrieve specific parameters overrides from PlatformConfig (#1093)

Fixes

  • Fix log for switching PQ to PV (#1067)
  • At most one flow/factor states calculation for one contingency in DC sensitivity analysis (#1061)
  • Security Analysis: fix Generator initialTargetP in OperatorStrategies (#1069)
  • AC loadflow: no network update on NO_CALCULATION (#1075)
  • Fix LimitViolation data for three-windings transformers (#1076)
  • Fix StaticVarCompensator and VscConverter used as reference generator (#1078)
  • Fix slack distribution when reference generator is not participating element (#1084)
  • Fix unpaired DanglingLine simulated with split shunt admittance (#1098)
  • Fix SA exception "No slack bus for network" (#1097)

Quality

  • Extract Woodbury engine from DC sensitivity analysis (#1064)
  • Remove log.txt (#1066)
  • Move runDcLoadFlow from DC sensitivity analysis to DcLoadFlowEngine (#1082)
  • Move cleanContingencies from DC sensitivity analysis to PropagatedContingency utility method (#1081)

Documentation

  • Add styles for docs (#1065)
  • Add dark mode pi model (#1077)
  • Fix dead links in README.md (#1083)
  • Add documentation for HVDC lines (#1070)

v1.12.2

16 Jul 10:46
v1.12.2

Choose a tag to compare

Release notes

  • Bump powsybl-core to 6.4.1 (#1068)

v1.11.1

16 Jul 15:37
v1.11.1
a15cfbd

Choose a tag to compare

Release notes

  • Fix bus state for AC calculations (#1058)

v1.12.1

08 Jul 15:20
v1.12.1
e219fc4

Choose a tag to compare

Release notes

Fixes

  • Revert "Refactor DC Sensitivity Analysis with Woodbury engine (#1001)" (#1057)
  • Fix bus state for AC calculations (#1058)
  • Extract ConnectivityBreakAnalysis and ComputedContingencyElement from DcSensitivityAnalysis (#1059)

V1.12.0

03 Jul 12:07
v1.12.0
aba7d3a

Choose a tag to compare

Important

⚠️ Do NOT use this version.
The DC Sensitivity Analysis refactoring introduces a huge memory consumption which leads to OutOfMemoryErrors.
Use powsybl-open-loadflow 1.12.1 instead.

Release notes

Upgrade to PowSyBl Core 6.4.0 (#1034, #1054)

Features

  • Improve transformer voltage control AFTER_GENERATOR_VOLTAGE_CONTROL (#1032)
  • Implement minTargetP and maxTargetP from ActivePowerControl extension (#1043)
  • Fictitious generators and condensers controlling voltage even if stopped (#1044)

Fixes

  • Fix limits handling in slack distribution on generators (#1041)

Dependencies

  • Upgrade to PowSyBl Core 6.4.0 (#1034, #1054)
  • Upgrade to PowSyBl Parent 18 (#1034)

Quality

  • Refactor DC Sensitivity Analysis with Woodbury engine (#1001)

V1.11.0

24 Jun 13:38

Choose a tag to compare

Release notes

Fixes

  • Fix and improve reactiveRangeCheckMode parameter documentation (#1049)
  • Fix allowed direction in incremental outer loops (#1052)
  • Fix state monitor duplicated results with tie lines (#1051)
  • Use existing threshold for filtering sensitivity of injection over voltage and voltage over injection (#1047)
  • Fix cache invalidation when change on another component (#1039)
  • DC security analysis: RHS is not invalidated (#1042)
  • Fix bus imbalance with slack distribution on load (#1040)
  • Fix transformer voltage control outer loop AFTER GENERATOR (#1038)
  • Fix Q dispatch not accounting for plausible reactive power range (#1037)

Quality

  • Readthedocs: simple transfer from website (#1046)

v1.10.0

27 May 14:05
v1.10.0
04f81d5

Choose a tag to compare

Release notes

  • Add Battery case for getIdentifiable for Propagated Contingency (#1018)
  • Absolute generator action ignores post-contingency slack (#1017)
  • Support generator remote reactive control on 3 windings transformer terminal (#1026)
  • Improve logging, reporting and LF results for components without generators (#919)
  • Report network angle reference bus and slack bus(es) after network loading (#1029)
  • Use IIDM OverLoadManagementSystem (#946)
  • Improve LoadFlowResult ComponentResult statusText (#1023)
  • Add reports in LfNetworkLoaderImpl (#1020)
  • Check target voltage plausibility on Transformers and Shunt Compensators (#1030)
  • Add operator strategy simulation report node (#1031)
  • Slack bus relocation (#923)
  • Minimal support of limit reductions for security analysis (#1011)

Fixes

  • Fix debugDir parameter possible values (#1021)
  • Fix Battery update state after voltage control (#1027)
  • Fixed Static VAR Compensator OFF mode having NaN P and Q results (#1033)
  • Connectivity data in DC sensitivity analysis (#1035)
  • Secondary voltage control: re-enable generators at limit when updating a control zone (#1022)

Quality

  • Add missing spdx license identifier (#1019)

V1.8.2

05 Apr 14:45

Choose a tag to compare

Release notes

Fixes

  • Support HVDC AC emulation simulation in DC Load Flow (#1013)